Muting with MF-T Reflex and MF-L Reflex Units
MF-T Reflex and MF-L Reflex are muting units with integrated retro-reflective photocells in the same profile type as the Focus Light Curtain/Grid. No additional sensors are required because the muting units contain the required components. The Reflex series simplifies the set up of muting sensors, as only 1 side requires a cable connection. The reflective side is a polarized reflector bar. MF-T Reflex and MF-L Reflex are connected directly to the Focus Receiver with M12 connectors. MF-T Reflex (Option 3)MF-T Reflex contains four transmitters/receivers and a separate reflector unit. Range 6m. Used in the muting mode for transport of material into and/or out of hazardous areas. For other functions refer to Option 1. This unit, together with light beam F4-K1C-500 provides electrical connections on only one side. MF-L Reflex (Option 4)MF-L Reflex contains two transmitters/receivers and a separate reflector unit. Range 6m. Used in the muting mode for transport of material into and/or out of hazardous areas. For other functions refer to Option 2. This unit, together with light beam F4-K1C-500 provides electrical connections on only one side. Note: MF-L Reflex unit is primarily intended for material transport “out” of a working area. The standard Focus Light Curtain/Grid delivered does not function together with the MF-L Reflex version. The Focus Light Curtain/Grid L version needs to be ordered separately, as well as the MF-L unit.
Note: The muting sensors A and B must be placed so that the sensor A is always activated at least 30 ms before sensor B.
D: indicates the minimum length of the material that is to actuate the muting sensors that must be maintained during the passage through the light curtain/grid.
d2: indicates the measurement between the two pre-assembled muting sensors within the MF-T Reflex andMF-L Reflex (= 150mm).
|

MF-T / MF-L Reflex Muting Units
Muting with MF-T Reflex and MF-L Reflex Units