Innovations in Machine Safety

Quick-Guard® - Assembly (Standard Version)

Assembly of the Quick-Guard® system is very easy. All components are very light in weight and ergonomic in form. This enables, in most cases, one man to be able to assemble both simple and complex structures with ease using very few different types of fixing components.

All fixtures can be mounted easily from "outside" by using the specially designed "locking nut" which can be located anywhere in the extrusion channel. The fixture components-by means of integral locating keys-ensure correct angles are achieved and enable the number of bolts/nuts to be reduced to half of what would otherwise be required.

Step1

Premount floor fixtures by first loosening the screw counter-clockwise. Then tighten the screw clockwise in the usual way. The nut will then automatically locate into the correct position and mechanically lock the fixture into the profile.

Step 2

Attach lower horizontal extrusion between vertical posts. Use a distance block to ensure the correct distance from the floor.

Step 3

Insert infill panel and fix middle horizontal extrusion. The distance between the profiles is the width of the infill minus 20 mm.

Step 4

Insert top infill panel. Fix top profile with fittings on the top on both sides.

Step 5

Fix top extrusion with fittings on both sides and fix the poles to floor.

Step 6

Secure infill sheet with plastic strip or Netlock fixings. Choice of Netlock is dependent upon mesh type used.