Innovations in Machine Safety

Technical Data - Fox (all versions)

Manufacturer.............................. JOKAB SAFETY

Color............................................ yellow and black

Weight (approx. with safety cover)
Fox 1
............................................................... 1.7 kg
Fox 2............................................................... 3.0 kg

Ambient Operating Temperature.......................
                                                        -15°C to +60°C

Material
Safety Cover......................................... Aluminum
Pedal......................... Shockproof thermoplastic

Rating Insulating Voltage Ui.................... 690 V

Connection Cable Cross Sections
Single Resp. Multi-Strand
................. 1 - 4 mm2

Fine Wire with Core end Bush
(DIN 46228)
.................................. 0.75 - 2.5mm2

Terminal Screws............................................. M4

Short Circuit Protection,
Fusible Cut-Out (gL)............................. 25A max.

Requirements for Isolators
compiled with up to.................................. 480V~

Switching Capacity AC-15.......220 - 240 V, 6A
                                                        380 - 440 V, 4A
                                                                  500 V, 3A

Mechanical Life (Number of Operations)
Position 3.................................................. 3 x 105
Position 1.................................................. 1 x 106

Degree of Protection as per
EN 60529, DIN VDE 0470/1........................ IP65

 

Pedal Function - Fox

  1. The Pedal (A) is in its initial position. The contacts are open and the machine is stopped.
  2. The contacts are closed when the pedal (A) is pressed down until the distinct contact point (B) is reached. The machine starts.
  3. If the operator in a panic situation presses the pedal to the bottom, a stop signal is immediately sent to the machine (the contacts open). The switch is mechanically locked in this position and it has to be reset before a new start can be made.
  4. Reset: Only after resetting the knob (C) will the contacts be disengaged and the pedal is now in its initial position (A).

Versions - Fox

Note: The Pedal is also available in a two-position execution.