RT7 Safety Relay
|
Universal Relay with Delayed 'Stop' Outputs
|
|
The RT7 is a universal relay that can be used to supervise both safety devices and the internal safety of your machinery. In addition, you can select the safety level that is required for each installation. All this is possible because the RT7 has the most versatile input options arrangement available on the market. The RT7 can therefore replace many other relays.
The RT7 has four (4 NO) dual safety outputs of which two may be delayed for up to three seconds in order to achieve a safe and 'soft' stop. A 'soft' stop allows machinery to brake and stop gently before power is removed. A 'soft' stop has many benefits: The machinery life will be prolonged, processed products will not be damaged, and restarts from the stopped position are made possible and easier.
Another option with the RT7 is manual or automatic resetting. A manual supervised reset is used for gates and other safety devices that can be bypassed, while an automatic reset is used for small safety hatches if deemed appropriate from a risk point of view.
In addition, the RT7 has information outputs that follow the inputs and outputs of the relay. These outputs indicate if for example a gate is opened or closed, if there is a delay or if the relay needs to be reset.
Choose the RT7 to simplify your safety circuits and reduce your costs.
|
Applications:
- Emergency Stops
- Light Curtains
- Three Position Devices
- Interlocked Gates/Hatches
- Magnetic Switches
- Light Beams
- Safety Mats
- Contact Strips
- Foot-Operated Switches
Features:
- Five input options
- Single or dual channel input
- Manual supervised or automatic reset
- Test input for supervision of external contactors
- Width 45 mm
- LED indication of supply, inputs, outputs, short-circuit and low voltage level
- 4 NO/1 NC relay outputs, 2 NO outputs can be delayed for soft stops
- Delay times:
- RT7A 0; 0.5; 1.0; 1.5 s
- RT7B 0; 1.0; 2.0; 3.0 s
- Three voltage free transistor information outputs
- 24 VDC
- 24, 48, 115 or 230 VAC
- Quick release connector blocks
|
| |
 |
 |
|
Approvals

|