Innovations in Machine Safety

JSNY10 Rope Pull Switch - Ordering Data


JSNY10

Switch


JSNY10-K

Mounting Kit

25 m

Plastic-coated steel cable wire

1 piece

Wire turnbuckle

4 pieces

Thimble

4 pieces

Wire clamp

5 pieces

Eyebolts with nuts


JSNY10-W3

Wire plastic-coated red

3 mm/4 mm (core/sleeve) per meter

 

JSNY10-S6

Eyebolt

M6x50


JSNY10-M6

Nut

M6 (to eyebolt)


JSNY10-V6

Wire turnbuckle

M5x50


JSNY10-L3

Wire clamp, duplex


JSNY10-T4

Wire thimble


Rope supports should be attached at a height of at least 20-25mm above the surface where the switch is to be installed.

Turnbuckles may be used to tune the pull-rope system to the correct tension.

A medium operating temperature should be maintained during installation.

The rope should be pulled heavily several times, then the tension of the rope should be readjusted to compensate for the elongation of the rope resulting from thimble distortion.