JSNY5 A/B Safety Interlock Switch
|
Technical Data
|
|
Manufacturer................................. JOKAB SAFETY
Ordering Data
Actuator holding force 10 N........................ JSNY5A
Actuator holding force 30 N........................ JSNY5B
Color...................................... black and yellow label
Weight.................................... approximately 0.13kg
Enclosure/Cover............................. PA 6 (UL94-VO)
Actuator............................................... steel actuator
Min. Opening Radius for Actuator
on a Hatch.................................................... 150 mm
Ambient Air Temperature............. -30ºC to +80ºC
Contacts (actuator in)........................ 2 NC + 1 NO
(NC are direct opening action)
Mechanical Life......... 1 million switch operations
Max. Switching Frequency.......................... 30/min
Fixing............................ body 2 x M5, actuator 2x M5
Cable Entry........................................... 2 x M20 x 1.5
Degree of Protection................. IP65 IEC 529/DIN
VDE 0470 T1
Rated Insulation Voltage......................... 400 V AC
Rated Operational Current.................................. 6A
Utilization Category........................... AC-15/DC-13
Short-Circuit Protection..... Fuse 6A slow acting,
16A quick acting
CSA.......................... 6A 300V AC B300 (same pol.)
Protection Class................................................ IP65
|
|
 |
|
|
Contact Description
|
Accessories and Spare Parts
|
Overlapping Contact 33-34
The overlapping contact 33-34 enables operational status indication of e.g. incorrect adjustment of switch before the positive forced disconnect NC contacts open.
|
 |
- Standard actuator (JSNY1N)
- Actuator with horizontal adjustment
- Actuator with vertical adjustment
- Actuator with holding force 100 N
- M20 cable gland
- M20 adaptors
- Snap-on plastic cover
|
|
Mounting Description
|
Easy Accessibility for Wiring
The snap-on cover is released by a screwdriver and can be opened to an angle of 1350 providing easy access to the wiring terminals. Should the snap-on cover not provide adequate security, a retaining screw can be used.
|
Protected Contact Block
A transparent cover protects the contact block from external elements during the installation and wiring process.
|
Prevention of Actuator dismantling
A cover plate with a one-way snap-fit which seals the mounting screws prevents unauthorized dismantling of the actuator assembly. The cover plate must be mounted to prevent overtravel of the switching mechanism.
|
|
|