Manufacturer.................................. JOKAB SAFETY
Ordering Data...................... Adam M12, Adam 3 m
Adam 10 m, Adam E10, Adam EC,
Eva, Eva E and Eva EC
(Adam EC and Eva EC
can only be ordered together.)
Safety Category together with Vital
(according to EN 954-1).......................................... 4
Color................................................ yellow and black
Weight
Adam M12............................................................ 30 g
Adam 3 m........................... 220 g (including cable)
Adam 10 m......................... 650 g (including cable)
Adam E10 m...................... 660 g (including cable)
Adam EC............................ 660 g (including cable)
Eva......................................................................... 26 g
Eva E..................................................................... 36 g
Eva EC.................................................................. 36 g
Power Supply......... 17 - 27 VDC, ripple max 10%
Power Consumption
Adam without info output.............................. 45 mA
Adam with info output.......................... max. 55 mA
Max. Cable Length......... see Vital Technical Data
Ambient Temperature
Operation.......................................... -40ºC to +70ºC
Storage.............................................. -40ºC to +70ºC
Protection Class
Eden/Eden E........................................... IP67/IP69K
Mounting............. 4 pcs. M4 screws + DA2 spacer
Max torque 0.5 Nm
(screws should be locked with loctite or similar)
Detection Distance Max
Adam/Eva 15 +/- 2 mm........................ Flash 2 mm
before red position
Adam/Eva 12 +/- 2 mm........................ Flash 2 mm
before red position
Adam/Eva EC 10 +/- 2 mm................. Flash 2 mm
before red position
Hysteresis........................................... approx. 1 mm
Metal may have influence on detection
distance. This can be prevented by
protection plates, DA1.
Life........................................................... >107 cycles
|
|
Mimimum distance to metal when
there is metal on one or more sides.
Adam/Eva (1)..................................................... 0 mm
Adam/Eva (more)...........................................2.5 mm
Adam EC/Eva EC, Adam E/Eva E(1)............. 0 mm
Adam Ec/Eva EC, Adam E/Eva E (more)....50 mm
Minimum Distance between Eden Pairs.. 50 mm
Material............... Macromelt (based on polyamid)
(Eden E and Eden EC is also covered
by polypropen)
Chemical Resistance
Macromelt
Good........................... cutting oils, vegetable and
animal oils, hydrogen peroxide,
diluted acids and bases
Not recommended..... alcohol and strong acids
PU (Eden E and Eden EC)
Good........................... cutting oils, vegetable and
animal oils, hydrogen peroxide,
diluted acids and bases, alcohols
Not recommended.......... strong oxidating acids
LED on Adam
Green................................. Eva within range, safety
circuit closed (door closed)
Flashing............................ Eva within range, earlier
safety circuit open (door closed)
Red...................................... Eva out of range, safety
circuit open (door open)
Fast Flashing.... Eva within 2 mm from maximum
sensing distance (door closed)
Cable.................. 3 or 10 m, 0/ 5.7 mm, black PVC
5 x 0.34 mm2 + screen, UL 2464
Connector........................ M12: 5-pin male contact
Connections
Brown (1)..................................................... +24 VDC
White (2)...................................... dynamic signal in
Blue (3).......................................................... 0 VDC
Black (4).................................... dynamic signal out
Grey (5)............................ info output (see below)
(24 VDC when LED is green or flashing
(tolerance -2 VDC) 10mA max
0 VDC when LED is red
(tolerance +2 VDC)
Warning: Incorrect connection may cause