Software and Logger

Smart Software controls the collection of data. The software processes the data and presents it on the screen as values and graphs. Smart Logger is a collector of data. It has the following inputs: 8 digital I/O, one input for an incremental sensor (for position and speed) and an analogue input. All stopping units and sensors are supplied power from the SM6 AC/DC Power supply and the Smart Logger.

    Current Consumption............................................ max 100 mA
    Size................................................ 242 x 166 x 42 mm (WxHxD)


SM2 - Push Button Stop Unit

Used with Smart for Stop Time measurements without electrical connection to Stop circuit of machine. Stop signal given manually. The pushbutton on the underside of the stop unit initiates stop time when it is pressed to measure the stop times of emergency stops, or released, for the measurement of stop times on two-hand units, depending on the position of the pushbutton. Connected to Smart Loggervia 8 pin plug.

     Applications........... Two-Hand Device, Emergency Stop, etc.
     Size.................................................. 50 x 100 x 25 mm (WxHxD)


SM3 - Relay Contact Stop Unit

Used with Smart for Stop Time measurements with electrical connection to machine. Stop signal is given either manually or automatically. Connection to Smart Logger via 8 pin plug.

     Applications........................................ All Stop & Safety Circuits
     Relay Outputs............................................................ 2 NO, 2 NC
     Size.................................................... 85 x 72 x 49 mm (WxHxD)


SM11 - Stop Flag Unit

Used with Smart for Stop Time/distance measurements. When the unit is activated the flag interrupts the light curtain and stops the machine. Connection to Smart Logger via 8 pin plug. Use SM12 to charge this unit.

     Applications...................................... Light Curtain, Light Beam
     Fixing........................................... Table Mounting or a standard
                                                                    1/4" camera mount fitting
     Size................................................... 145 x 85 x 37 mm (WxHxD)
                                                                                     shaft ø3 45 mm


SM5 1250/2500 - Linear Transducer

Digital position transducer for connection to Smart. Outputs provide position accuracy of machine part with a resolution of 0.1mm. Housing with magnetic retainers. Thin steel wire with magnet for attachment to moving part. Connected to Smart Logger via 5 pin plug.

     Max. Travel........................................................... 1250/2500 mm
     Max. Speed............................................................................ 5 m/s
     Size (1250)..................... 100 x 95 x 100 mm (approx. WxHxD)
     Size (2500).................. 110 x 103 x 116 mm (approx. WxHxD)


SM7 - Rotary Transducer

The transducer SM7 is used for stop timing of rotational machinery parts (turning machine, paper machinery, etc.). Support with ball links and single-knob locking. Magnetic fastener in base with on/off control. Measuring wheel with rubber surface. Connected to Smart Logger via 5 pin plug.

     Circumference of Measuring Wheel............................125 mm
     Height......................................................(max.) approx. 300 mm
     Max. Speed.............................................................................5 m/s