Tina 1A, 2A, 3A, 4A, 6A, 7A and 8A
|
Technical Data
|
|
Manufacturer.................................. JOKAB SAFETY
Ordering Data.... Tina 1A, 2A, 3A, 4A, 6A, 7A & 8A
(for M12 contacts and cables
see component order list)
Safety Category with Vital
(according to EN 954-1).......................................... 4
Color.................................................................... black
Material...................................... based on polyamid
Current Consumption
Tina 1A and 2A................................................. 17 mA
Tina 3A, 6A and 7A.......................................... 47 mA
Tina 4A............................................................... 10 mA
Tina 8A............................................................... 15 mA
Max. connected
units/cable length........................ see data for Vital
Tina 3A, 6A and 7A
Current through safety device contacts....... 12 mA
Short circuit current between contacts........ 10 mA
Max. Cable Length......... see Vital Technical Data
Temperature Range
Operation........................................... -10ºC to +55ºC
Storage............................................... -30ºC to +70ºC
|
|
LED on Tina 1A, 2A, 3A, 6A and 7A
Green.................. Safety device ok, safety circuit ok
Flashing..... Safety device ok, safety circuit broken
Red............ Safety device and safety circuit broken
(Red, not for Tina 1A and 2A)
Connections
Brown (1)..................... 17 - 27 VDC, ripple +/- 10%
White (2)............................. dynamic input signal in
Blue (3)........................................................... 0 VDC
Black (4)........................ dynamic output signal out
Grey (5) (not Tina 1A)................. indication output
(see below)
(24 VDC when LED is green or
flashing/tolerance -2 VDC/10mA max.)
(0 VDC when LED is
red/tolerance +2 VDC)
Connection block 5 - 8 Tina 4A status for
connected unit according to connection 5
Connection block 5 - 12 Tina 8A
see above 5 - 8 Tina 4A
Note: Shielded cable is recommended
between cabinet and Tina 4A/8A. Shield
to be connected to ground in cabinet only.
Protection Class
Tina 1A, 2A, 3A and 6A..................................... IP 67
Tina 7A................................................................ IP 20
|
|
|
|
Connection - Tina 1A, 2A, 3A, 4A, 6A, 7A and 8A
In order to achieve category 4 according to EN 954-1 the connection to the safety device must be made inside an enclosure - I.e. safety switch, E-stop...
|
|
See connection example HH3300D
|
|
See connection example HH3300D
|
|
See connection example HH3303A
|
|
See connection example HA3307A
|
|
See connection example HH3304A
|
|
See connection example HH3300D
|
|
See connection example HH3300C
|
|
|