• Safety Switches and E-Stop Product Launch
    Safety Switches and E-Stop Product Launch 2012 Safety Switches and Emergency stop Product Launch. Over 1200 different versions capable of satisfying even the most demanding applications.
    More Information
  • Pluto Safeguards Robotic Application
    Pluto Safeguards Robotic Application Pluto Safety PLC safeguards and controls a fully automated robotic stampling application to Safety Category 4.
    Pluto Application Examples (PDF 864KB)
  • Stainless Steel Switches and E-Stops
    Stainless Steel Switches and E-Stops Stainless Steel Safety Switches and Emergency Stops for the Food, Beverage, Chemical and Pharmaceutical Industries.
    Brochure (PDF 526KB)
  • Anti Tie-down 2 Hand Control Station
    Anti Tie-down 2 Hand Control Station Category 4 anti tie-down, anti repeat mobile 2 hand control stations custom designed for your application.
    JSTD25 Two Hand Stations (PDF 1.1MB)
  • Cheat Safe three-postion device with hand recognition
    Cheat Safe three-postion device with hand recognition The three-position device JSHD4 has sensors which ensure that it is a human hand holding it. It is no longer possible to expose the operator or holder to danger by trying to lock the three-position device in run mode.
    JSHD4 (PDF 1.6MB)
Text Size
Fri, May 18, 2012

More I/O's on new Pluto B46-6 Safety PLC

Benefits Include

  • Lower cost per I/O
  • It is possible to build larger systems
    32 B46 PLUTO's on the same bus = 32 x 46 I/O
  • Complete machine control now made easier

Pluto

The Pluto B46-6, is the most powerful safety PLC yet, but with a width of just 90mm. It has been developed by the need for a compact safety PLC with more built-in I/O’s. The B46-6 has a total of 46 I/O’s, 6 of which are individual safe outputs. Also, 16 I/O’s can be used as either inputs or outputs and there are 24 inputs designated for safety and other devices. Programming is via the intuitive Pluto Manager Software and is based on ladder logic, making PLUTO suitable for both safety monitoring and control of smaller machines. An operating panel (HMI) can be connected directly to the serial interface or to the safety Can-Bus.

Gateways for Pluto Safety PLC to major bus-systems

Jokab Safety has released 3 new Gateways for bi-directional communication between the Pluto Safety PLC System and other field bus systems. The supported protocols are Profibus-DP, DeviceNet and CANopen. This enables the customer to choose their machine safety solution from Jokab Safety independent from what higher level bus-system they use for the standard machine control. Gateways for Ethernet are also under development and are expected to be released during 2007.

Technical Data Pluto B46-6

  • Failsafe inputs
  • IO-I7 + I30-I37 + I40-I47 + I50 + I51+24 V
  • (for PNP sensors)
  • IQ10-IQ17 + IQ20-IQ27+24 V (for PNP sensors)
  • (also configurable as non-failsafe outputs)
  • Max. over voltage30 V continuously
  • Filter time (standard)5 - 10 ms, software
  • Safety Output
  • Q2-Q3:Solid state, -24 VDC
  • Output voltage tolerance:Supply voltage
  • -1.5 V at 800 mA
  • Max. load / output1.5 A
  • Outputs, non-failsafe
  • IQ10-IQ17 + IQ20-IQ27Transistor +24V,
  • PNP open collector
  • (also configurable as failsafe outputs)
  • Max load/output800 mA
  • Safety Bus
  • Max. units on the bus32
  • Bus cable lenght130m at 400 kb/s (standard)
  • (other combinations are possible)
  • Response time
  • Software setting *NO Filt*
  • reduces the response time-5 ms
  • Response time over the bus
  • (normal function):+10 ms
  • Programming facilities
  • Program languageLadder or boolean algebra
  • TÜV approved function blocks
  • Arithmatic functionsYes
  • Program memory32k
  • Internal memories500
  • Registers150
  • Timers50
  • Enclosure95 x 84 x 118 mm (w x h x d)